building. climate. excellence.
building. climate. excellence.
Indirect unvented cylinders for potable water installations.
Economical, high performance, stainless steel vessels for hot and cold water storage. Tanks for use in all closed circuit water supply systems, demand satisfied by storage volume.
FlexTherm Supastor indirect unvented cylinders have been designed around UK specifications, being compact, easy to install with 'in-line' connections and are supplied with all necessary controls including a 2 port motorised valve.
Application of Use: Domestic and Commercial.
Type | Capacity [l] | Heating surface area [m2] | Heating capacity [kW] | Water capacity [l/h] | Dimensions | Insulation colour | Weight [kg] | Order Code | |||
Ø [mm] | H [mm] | ||||||||||
FlexTherm Supastor Indirect 125 + Kit | 125 | 0.46 | 21.7 | 415 | 550 | 1020 | white | 36 | 1 | 45209 | |
FlexTherm Supastor Indirect 150 + Kit | 150 | 0.56 | 23.0 | 440 | 550 | 1180 | white | 42 | 1 | 45210 | |
FlexTherm Supastor Indirect 170 + Kit | 170 | 0.56 | 22.5 | 430 | 550 | 1260 | white | 48 | 1 | 45211 | |
FlexTherm Supastor Indirect 200 + Kit | 200 | 0.86 | 31.7 | 605 | 550 | 1440 | white | 50 | 1 | 45212 | |
FlexTherm Supastor Indirect 250 + Kit | 250 | 0.93 | 33.2 | 635 | 550 | 1760 | white | 59 | 1 | 45213 | |
FlexTherm Supastor Indirect 300 + Kit | 300 | 1.31 | 42.6 | 815 | 620 | 1590 | white | 65 | 1 | 45214 | |
FlexTherm Supastor Indirect 500 + Kit | 500 | 1.60 | 50.2 | 960 | 710 | 1900 | white | 100 | 1 | 45215 | |
FlexTherm Supastor Indirect 800 + Kit | 800 | 2.21 | 82.2 | 1570 | 820 * | 1850 | white | 165 | 1 | 45216 | |
FlexTherm Supastor Indirect 1000 + Kit | 1000 | 2.21 | 80.1 | 1530 | 820 * | 2300 | white | 197 | 1 | 45217 |
* Dimensions excluding insulation.
Technical specifications | FlexTherm Supastor Indirect | ||||||||
125 | 150 | 170 | 200 | 250 | 300 | 500 | 800 | 1000 | |
Energy Efficiency (EN 12897) [W] | 37 | 37 | 37 | 36 | 37 | 37 | 36 | n/a | n/a |
Energy label | B | B | C | C | C | C | C | n/a | n/a |
Total heat loss [W] | 48 | 52 | 62 | 77 | 83 | 94 | 133 | 133 | 231 |
Standing heat loss [kWh/24hr] | 1.15 | 1.25 | 1.49 | 1.85 | 1.99 | 2.26 | 3.19 | 3.19 | 5.54 |
Heating surface area [m2] | 0.46 | 0.56 | 0.56 | 0.86 | 0.93 | 1.31 | 1.60 | 2.21 | 2.21 |
Coil pressure drop [mbar] | 40 | 42 | 42 | 77 | 80 | 92 | 96 | 96 | 123 |
Rated power output 82/71 °C [kW] | 21.7 | 23.0 | 22.5 | 31.7 | 33.2 | 42.6 | 50.2 | 82.2 | 80.1 |
Water capacity [l/h] | 415 | 440 | 430 | 605 | 635 | 815 | 960 | 1570 | 1530 |
Primary flow rate required for primary heating power [l/min.] | 25 | 34 | 34 | 42 | 42 | 59 | 60 | 92 | 92 |
Heat up time [mins] * | 21 | 23 | 25 | 30 | 34 | 39 | 48 | 50 | 57 |
Re-heat-up time 70% draw off [mins] * | 14 | 15 | 17 | 20 | 22 | 24 | 31 | 33 | 37 |
Hot water storage tank volume [l] | 126 | 151 | 169 | 200 | 250 | 294 | 498 | 770 | 1000 |
Expansion vessel (Airfix P, 10 bar) [l] | 12 | 12 | 12 | 12 | 12 | 12 | 24 | 35 | 35 |
Weight empty [kg] | 36 | 42 | 48 | 50 | 59 | 65 | 100 | 165 | 197 |
Weight full [kg] | 159 | 190 | 216 | 250 | 305 | 354 | 495 | 916 | 1193 |
* Heat up time and re-heat time are based on a primary flow temperature of 60 °C and a temperature rise from 15 °C to 60 °C.
n/a = not applicable.
Type | Distance from floor to connection centres | ||||||||
A [mm] | B/C [mm] | D [mm] | E [mm] | F [mm] | K [mm] | M [mm] | N [mm] | O [mm] | |
FlexTherm Supastor Indirect 125 | - | 196 | 299 | 421 | 471 | - | 651 | 751 | 1020 |
FlexTherm Supastor Indirect 150 | - | 196 | 341 | 486 | 536 | - | 786 | 911 | 1180 |
FlexTherm Supastor Indirect 170 | - | 196 | 341 | 486 | 536 | - | 881 | 1031 | 1260 |
FlexTherm Supastor Indirect 200 | - | 196 | 376 | 646 | 696 | - | 981 | 1211 | 1440 |
FlexTherm Supastor Indirect 250 | - | 196 | 396 | 676 | 726 | - | 1271 | 1531 | 1760 |
FlexTherm Supastor Indirect 300 | - | 218 | 448 | 733 | 783 | - | 1153 | 1333 | 1590 |
FlexTherm Supastor Indirect 500 | - | 225 | 500 | 835 | 885 | - | 1440 | 1640 | 1640 |
FlexTherm Supastor Indirect 800 | ? | 380 | 650 | 900 | 960 | 1160 | 1240 | 1490 | 1490 |
FlexTherm Supastor Indirect 1000 | ? | 380 | 650 | 900 | 960 | 1160 | 1575 | 1920 | 1920 |
Type | Connections | ||||||||
Drain (A) | Boiler return (B) | Cold water inlet (C) | Aquastat pocket * (D) | Boiler Flow (E) | Immersion Heater (F & K) | Secondary Return (M) | T&P Relief Valve (N) | Hot Water Draw Off (O) | |
FlexTherm Supastor Indirect 125 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 150 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 170 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 200 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 250 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 300 | - | 22 mm | 22 mm | ? | 22 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 22 mm |
FlexTherm Supastor Indirect 500 | - | 28 mm | 28 mm | ? | 28 mm | 1 3⁄4" F | 1⁄2" F (Blank) | 3⁄4" F | 28 mm |
FlexTherm Supastor Indirect 800 | 1" F | 1" F | 1 1⁄2" F | ? | 1" F | 1 3⁄4" F | 1 1⁄2" F | 3⁄4" F | 1 1⁄2" F |
FlexTherm Supastor Indirect 1000 | 1" F | 1" F | 1 1⁄2" F | ? | 1" F | 1 3⁄4" F | 1 1⁄2" F | 3⁄4" F | 1 1⁄2" F |
* 800 - 1000 Litres: Sensor
Property Type | Size [l] |
1/2 beds with 1 bath / shower | 125 |
3 beds with 1 bath / shower | 150 or 170 |
4 beds with 1 bath / shower | 170 or 200 |
2/3 beds with 2 baths / showers | 200 |
4/5 beds with 2 baths / showers | 200 or 250 |
Sports club, restaurant etc. | 300 or 500 |
Hotels, schools etc. | 800 or 1000 |
Immersion sizes | FlexTherm Supastor Indirect | ||||||||
125 | 150 | 170 | 200 | 250 | 300 | 500 | 800 | 1000 | |
3 kW | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
6 kW | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
9 kW | n/a | n/a | n/a | n/a | n/a | n/a | ✓ | ✓ | ✓ |
12 kW | n/a | n/a | n/a | n/a | n/a | n/a | ✓ | ✓ | ✓ |
18 kW | n/a | n/a | n/a | n/a | n/a | n/a | n/a | ✓ | ✓ |
n/a = not applicable.
Flamco has been involved in the development, production and sale of high-quality components for use in HVAC systems since 1956. It is part of the stocklisted Aalberts NV, instituted in 1975. Along with Comap, which helps manage water and energy through its thermal and sanitary products that increase comfort in buildings, the Aalberts hydronic flow control business unit was constituted. Stronger together, Flamco and Comap will continue to build mission critical technologies to manage heating and cooling humanly with better financial and environmental efficacy. From source to emitter we partner with our customers to engineer seamless energy efficient hydronic systems for their building requirements.
comap.aalberts-hfc.com | aalberts-hfc.com
Stay up-to-date. Subscribe to our newsletter.
I agree to the processing of my personal data. Aalberts hydronic flow control attaches importance to your privacy.